1. Wire ropes for electric hoists should use wire contact wire ropes preferentially. Its structure type should conform to the rope 18×7 and rope 6×37 in GB/T8918, and its nominal tensile strength should be no less than 1570 MPa.
2. The wire rope should be arranged in order on the reel.
3. When the load is supported by multiple wire ropes, a pulley device that balances the force of each wire rope should be provided.
4. When the hook is at the lowest point of the working position, the safety ring of the wire rope on the reel must not be less than 2 turns (except for the number of turns of the fixed tail).
5. When fixing the wire rope with a wedge joint, it shall comply with the relevant provisions of GB/T 5973.
6. Electric hoists used for lifting molten metals should adopt effective radiation-proof heat separators and other measures for wire ropes.
Contal Us

Autor:

Mr. lily

Correo electrónico:

lily@chinaweldedmesh.com

Phone/WhatsApp:

+8618203280117

productos populares
Noticias de la exhibición
También te puede gustar
Categorías relacionadas

Contactar proveedor

Asunto:
Móvil:
Email:
Mensaje:

Tu mensaje MSS

Contal Us

Autor:

Mr. lily

Correo electrónico:

lily@chinaweldedmesh.com

Phone/WhatsApp:

+8618203280117

productos populares
Noticias de la exhibición
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Enviar